Robotics

Wissenschaftliche Publikation

Validation of Relevant Parameters of Sensitive Manipulators for Human-Robot Collaboration

Publikation aus Robotics
Mechatronische Systeme

David Kirschner , Andreas Schlotzhauer , DI Dr. Mathias Brandstötter, Univ.-Doz. DI Dr. Michael Hofbaur

Proceedings of the 26th International Conference on Robotics in Alpe-Adria-Danube Region (RAAD 2017). Turin , 6/2017

Abstract:

The development of sensitive manipulators has decisively enlarged the range of robot applications in recent years. This robot class enables direct interaction between humans and robots, even in an industrial environment. High demands from the industry are placed on robot Systems in general, such as robustness, precision, high and constant speed, etc., of which collaborative robots are not excepted. In this paper important parameters of sensitive robots are listed and well-known Systems from different manufacturers are compared by extensive measurements. Peculiarities are identi ed, analysed, and presented and valuable suggestions for programmers and applicators are derived.

 

Keywords: ABB YuMi, KUKA iiwa, Universal Robot UR3, sensitivity, force, pressure, accuracy, repeatability, measurement